Killark is a leading manufacturer of lighting fixtures and systems, designed for broad-based capabilities in wet, harsh and hazardous environments. When selecting a fixture, its ratings should match or exceed requirements based on the application and area of use, including appropriate light sources and the presence of hazardous or corrosive elements.
Fixtures utilizing Incandescent lamps include metallic and non-metallic types for use in wet/harsh and certain hazardous locations, as well as explosion-proof models for Class I, Division 1 (Groups A, B, C, D) areas, plus portable incandescent hand lamps.
Fixtures utilizing Compact Fluorescent lamps include corrosion resistant non-metallic series and compact or full size enclosed & gasketed styles for standard and certain hazardous locations. Explosion-proof fixtures and hand lamps housing compact fluorescent lamps are also available.
Fixtures utilizing HID Sources include compact and restricted breathing models for medium base lamps and full size versions for mogul base lamps. Use in wet, NEMA 4X (hose down & corrosion resistant) and certain hazardous locations. Also featured are explosion-proof fixture types for medium base and mogul base lamps.
Fixtures utilizing Linear Fluorescent lamps include metallic and non-metallic fixtures and exit lights for wet, NEMA 4X and certain hazardous areas. Explosion-proof series are suitable for use inside paint spray booths.
Floodlights & Wall Mount Fixtures range from quartz lamp types for standard locations to floods in aluminum or stainless steel for wet and marine applications. Explosion-proof HID trunnion mount and portable floodlights, plus wall pack HID, complete this category.
Emergency Strobe Signal Lighting includes a compact strobe for wet and certain hazardous locations plus an explosion-proof strobe signal unit also rated for NEMA 4X and marine service.
Emergency Lighting (Battery Backed) Fixtures include enclosed & gasketed compact fluorescent emergency units for NEMA 4X and hazardous locations plus an explosion-proof version. Also available are linear fluorescent in metallic housing, plus an explosion-proof fixture utilizing high intensity halogen lamps.
Fixture Hangers, Fittings and Adapters include ball joint, hook/loop and flexible mount hangers plus explosion-proof combination splice box/hangers and flexible pendant fixture hangers. Also featured are pendant sealing fittings and adapters for retrofitting Killark HID fixtures to competitors ceiling or wall mount splice caps.
Fixtures with Cenelec-European Ratings include "Certificate of Conformity" compact Zone 2 units and Zone 1 rated units for medium and mogul based sources, plus models for use with incandescent and compact fluorescent lamps. Also available are HID floodlights (restricted breathing construction) for Zone 2 areas in aluminum or stainless steel, as well as Zone 1 rated floods and non-metallic linear fluorescents.
|
V Series Incandescent Fixtures Use for task and general lighting in standard and wet locations |
 |
- Copper-free aluminum with epoxy/polyester finish
- Compact, durable, modular design fixture
- Models for NEMA 4 and certain hazardous locations
|
|
|
NV Series Non-Metallic Incandescent Fixtures Use for task and general lighting in corrosive environments |
 |
- Molded from 30% glass-filled thermoplastic polyester
- For wet, NEMA 4X and marine applications
|
|
 |
Back to top |
EMI Series Incandescent Fixtures Use where explosion-proof and NEMA 4X & Marine rated fixtures are required |
 |
- Compact in size with wireless design for fast installation
- Factory sealed no external seal needed
- Full range of accessories including exit signs and inner colored globes
|
|
|
DV Series Incandescent Fixtures Use for lighting in dust-ignition proof (Class II Div.1) locations |
 |
- Copper-free aluminum with epoxy/polyester finish
- Compact, durable, instant-on
|
|
 |
Back to top |
H Series Incandescent Fixtures Use where infrequent lighting of Class I, Div. 1 areas is required |
 |
- Copper-free aluminum with epoxy/polyester finish
- For mogul base 300 or 500 watt lamps
|
|
|
E Series Incandescent Fixtures Use for general or task lighting where Group A or Group B gases are present |
 |
- Copper-free aluminum with epoxy/polyester finish
- For medium base 200 or 300 watt lamps
|
|
 |
Back to top |
XHL Series Handlamps Use as supplementary illumination source in Class I, Div. 1 hazardous locations |
 |
- Phenolic handle for long service in rugged conditions
- Aluminum guard with heat & impact resistant globe
- Supplied with 100 watt rough service lamp
- Grommets included for use with user furnished SO cable
|
|
|
|
 |
Back to top |
NVQ Series Non-Metallic Compact Fluorescent Fixtures Use for task and general lighting in corrosive environments |
 |
- Molded from 30% glass-filled thermoplastic polyester
- For wet, NEMA 4X and certain hazardous locations
- Furnished with 18W compact fluorescent lamp
|
|
|
MBF Series Compact Fluorescent Fixtures Use for lighting wet, harsh (NEMA 4X & Marine), and certain hazardous locations |
 |
- Copper-free aluminum with epoxy/polyester finish
- External hardware is 316 grade stainless steel
- Compact and rugged design
- Furnished with lamps (up to 39W)
|
|
 |
Back to top |
VBF/VQF Series Compact Fluorescent Fixtures Use for lighting wet, harsh (NEMA 4X & Marine) and certain hazardous locations |
 |
- Copper-free aluminum with epoxy/polyester finish
- External hardware is 316 grade stainless steel
- Full sized with range of accessories and options, with lamps included
- World voltage on VQF (120-277VAC; 50/60 Hz)
|
|
|
EBF/EQF Series Compact Fluorescent Fixtures Use where explosion-proof and NEMA 4X & Marine fixtures are required |
 |
- Compact in size with wireless design for fast installation
- Factory sealed no external seal needed
- Full range of accessories including exit signs and inner colored globes
- Compact fluorescent lamp included
|
|
 |
Back to top |
XHLF Series Compact Fluorescent Handlamps Use as supplementary illumination source in Class I, Div. 1 hazardous locations |
 |
- No exposed metal parts
- Supplied with 26 watt lamp and light shield
- Grommet included for use with user furnished SO cable
|
|
|
|
 |
Back to top |
MB Series HID Fixtures Use for lighting wet, harsh (NEMA 4X & Marine) and certain hazardous locations |
 |
- Copper-free aluminum with epoxy/polyester finish
- External hardware is 316 grade stainless steel
- Compact design, for use with medium base HID lamps
- Restricted Breathing model (lower temperature codes) available
|
|
|
VM Series HID Fixtures Use for area illumination of wet, harsh (NEMA 4X & Marine) and certain hazardous locations |
 |
- Copper-free aluminum with epoxy/polyester finish
- External hardware is 316 grade stainless steel
- Full sized for mogul base lamps, with range of accessories and options
- Restricted Breathing model (lower temperature codes) available
|
|
 |
Back to top |
EM Series HID Fixtures Use where explosion-proof and NEMA 4X & Marine fixtures are required |
 |
- Compact in size with wireless design for fast installation
- Factory sealed no external seal needed
- Full range of accessories including exit sign and inner colored globes
- For use with medium base 35-150W HID lamps
|
|
|
EZ Series HID Fixtures Use where explosion-proof and NEMA 4X & Marine fixtures are required |
 |
- Full sized with wireless design for fast, easy installation
- Factory sealed no external seal needed
- Five mounting styles and options including HPS instant restart and ballast protection circuit plus Quartz emergency lighting
- For use with mogul base 50-400W HID lamps
|
|
 |
Back to top |
DBF Series Linear Fluorescent Fixtures Use in wet, NEMA 4 and certain hazardous locations where low mounting height and even light distribution from a linear type light source are required |
 |
- Sheet steel 20 gauge housing with continuous weld
- Electrostatically applied polyester finish
- Silicon rubber gasketing and heat tempered glass lens
|
|
|
SSHZ Series Linear Fluorescent Fixtures Use in wet, NEMA 4 and certain hazardous locations where low mounting height and even light distribution are required |
 |
- Seamless housing of 20 gauge 304 grade stainless steel
- External hardware of stainless steel
- Continuous silicone gasketing and heat tempered glass lens
- Acrylic lens option
|
|
 |
Back to top |
HFX Series Linear Fluorescent Fixtures Use in classified Class I, Div. 1 areas such as inside paint spray booths |
 |
- Copper-free aluminum construction with external stainless steel hardware
- Factory sealed no external seals required
- UL Listed & labeled for use inside paint spray booths and rooms
- Spring loaded sockets with relamping from either end
- Slide out ballast tray for easy maintenance
|
|
|
LZ2N Series Non-Metallic Linear Fluorescent Fixtures Use for lighting in corrosive environments and in certain hazardous locations |
 |
- Housing is one piece fiberglass reinforced polyester
- Lens of clear impact resistant polycarbonate
- World voltage (most models) 120-277V, 50/60Hz
- 2 and 4 models available
|
|
 |
Back to top |
LLN2/LLN1 Series Non-Metallic Linear Fluorescent Fixtures Use for lighting in corrosive environments and in certain hazardous locations |
 |
- FRP housing with single piece polycarbonate lens
- Single point latching mechanism
- LLN2 for North American Zone 2 applications, LLN1 for Zones 1& 2
- Mounting accessories (such as suspension & ceiling mounts) available
|
|
|
LLC Series Non-metallic Compact Linear Fluorescent Fixtures Use for task lighting or exit fixture in corrosive and certain hazardous areas |
 |
- FRP housing with single piece low glare polycarbonate lens
- Exit sign decals apply to clear lens
- LLC Series for North American Zone 2 applications
|
|
 |
Back to top |
QL Series Quartz Floodlights Use in standard locations to provide maximum light output with low initial cost |
 |
- Cast aluminum housing with heat dissipating fin system
- Tempered glass lens assembly with high temperature gasketing
- Accommodates up to 1500W quartz lamps
|
|
|
KF Series HID Floodlights Use for Wet/Marine/Shipboard applications plus in Class I, Div. 2 locations |
 |
- Housing of copper-free aluminum with corrosion resistant bronze finish
- All external hardware is stainless steel with continuous silicone gasketing
- Accommodates 150-1000W long life HID lamps
|
|
 |
Back to top |
KFSS Series HID Marine Floodlights Use for Wet/Marine/Shipboard applications plus in Class I, Div. 2 locations |
 |
- Type 316 stainless steel housing for maximum corrosion resistance
- Quick release SS lens latches, SS lens door chains, SS mounting yoke
- Accommodates 150-400W long life HID lamps
|
|
|
EZ Series HID Trunnion Mount Floodlights Explosion-proof & NEMA 4X rated fixture provides directional lighting in both vertical & horizontal planes when used with floodlight mounting hardware |
 |
- Copper-free aluminum housing with powder epoxy finish
- Factory sealed no external seal needed
- Accommodates 50-400W long life HID lamps
|
|
 |
Back to top |
EM/DM HID Portable Floodlights Provides emergency or maintenance lighting in wet and Class 1, Div. 1 areas |
 |
- Copper-free aluminum housing with safety yellow finish
- Strong base provides stability and temporary wall mounting
- Factory sealed 100 foot 16/3 SOW cord and HID lamp included
|
|
|
KWP Series HID Wallpack Luminaries Use where pleasing aesthetic appearance and suitability for NEMA 4X and Class I, Div. 2 locations, in a compact energy saving fixture, are requirements |
 |
- Copper-free aluminum construction with bronze finish
- Lens thermal shock and impact resistant prismatic borosilicate glass
- Accommodates 70-175W long life HID lamps
|
|
 |
Back to top |
GSH Series Compact Strobe Signal Lights Use as visual warning or status device in wet and certain hazardous locations |
 |
- Aluminum housing with polycarbonate lens
- High intensity Xenon flash lamp provides 400 candela with 60 flashes/min
- Four different globe colors. Can mount with globe in up or down position
|
|
|
ESX Series Strobe Signal Lights Use as visual warning device for Explosion-proof, NEMA 4X and Marine duty |
 |
- Copper-free aluminum housing with epoxy/polyester finish
- High intensity strobe provides up to 200 candela with 85 flashes/min
- Five different globe colors with four mounting styles
|
|
 |
Back to top |
DEB/VEB/VEQ Series Compact Fluorescent Emergency Lighting Fixtures Use to provide OSHA required 90 minutes of illumination for egress in certain hazardous locations and for NEMA 4X applications |
 |
- Continuous lighting under normal power with battery backup during power outages, or emergency only units that operate when power fails
- LED charging indicator light plus exit accessory
- Copper-free aluminum housing with epoxy/polyester finish
- World voltage (120-277V, 50-60 Hz) available on VEQ Series
|
|
|
EEQ Series Compact Fluorescent Emergency Lighting Fixtures Use to provide OSHA required 90 minutes of illumination for egress in areas requiring Explosion-proof and NEMA 3 rated fixtures |
 |
- Continuous lighting under normal power with battery backup during power outages, or emergency only units that operate when power fails
- LED charging indicator light plus exit accessory
- Copper-free aluminum housing with epoxy/polyester finish
|
|
 |
Back to top |
DBFE Series Linear Fluorescent Emergency Lighting Fixtures Use to provide OSHA required 90 minutes of illumination for egress in certain hazardous and NEMA 4 rated locations that require even light distribution |
 |
- Lighting under normal power with battery backup when power fails
- Sheet steel 20 gauge housing with continuous weld
- Electrostatically applied polyester finish with heat tempered glass
|
|
|
EBB Series Halogen Lamp Emergency Lighting Fixtures Use to provide OSHA required 90 minutes of illumination for egress in areas requiring Explosion-proof fixtures |
 |
- Lighting under normal power with battery backup when power fails
- Three high intensity lamps can be independently adjusted
- Remote test station (included) for fixture testing at ground level
- Copper-free aluminum housing with epoxy/polyester finish
|
|
 |
Back to top |
FKA/FH Series Fixture Hangers Use to hang fixtures (up to 125 pounds) in standard locations |
 |
- Ball joint permits fixture to hang plumb. Allows swing up to 20 degrees
- Copper-free aluminum with set screw to lock fixture stem in place
- FH Series serves as combination splice box and flexible hanger
|
 |
|
|
Hook/Loop and FH Series Fixture Hangers Use to hang fixtures (up to 125 pounds) in standard locations |
 |
- Hook/Loop hanger consists of a hook and safety bar, which allows conversion to a loop configuration as necessary
- FH Hook is an economical hanger for pendant fixtures
|
 |
|
 |
Back to top |
V Series Hanger Boxes and Covers Use to hang fixtures (up to 125 pounds) in standard and wet locations |
 |
- Combines splice box (in four configurations) and hanger in one unit
- Flexible hanger cover is cushioned to absorb shock and vibration
- Copper-free aluminum with set screw to lock fixture stem in place
|
 |
|
|
HXB/XFH Series Fixture Hangers Use to hang fixtures (up to 125 pounds) in Class I, Div. 1 hazardous areas |
 |
- Combines splice box and hanger in one unit
- HXB Series with four hubs in X configuration. XFH for through feed
- Copper-free aluminum with set screws to lock fixture stem in place
|
 |
|
 |
Back to top |
EKJ Series Flexible Pendant Fixture Hangers Suspends fixtures (up to 125 pounds) in Class I, Div. 1 hazardous & wet areas |
 |
- Permits fixtures to swing freely and to hang plumb
- Constructed of seamless bronze hose with brass outer braid and jute liner
- Provides electrical ground continuity without bonding jumper
|
|
|
JL/JAL Series Fixture Hangers Use to hang fixtures (up to 125 pounds) in Class I, Div. 1 hazardous areas |
 |
- Combines splice box and hub cover for mounting pendant fixtures
- Conduit openings in straight through or four hub configurations
- Copper-free aluminum with set screws and integral mounting lugs
|
 |
|
 |
Back to top |
ENY Pendant Seal Fittings Use to meet code requirements of a safety set screw when hanging fixtures |
 |
- Copper-free aluminum with set screws on each end
- For Class I, Div. 1 applications. Supports up to 125 pounds
|
|
|
VM Series Fixture Adapters Use to upgrade existing Crouse-Hinds&Reg; fixture cap to new Killark HID, compact fluorescent, or emergency units |
 |
- Patented design. For NEMA 4X and certain hazardous locations
|
|
 |
Back to top |
EAC/EZBA Series Fixture Adapters Use to upgrade existing Crouse-Hinds&Reg; Explosion-proof units to Killark |
 |
- Converted fixtures easily removed for service using EZ mounting system
|
 |
|
|
|
 |
Back to top |
ECJ Series Cenelec Rated Fixtures Use where restricted breathing type, Zone 2 area fixture is required |
 |
- Compact size and low weight
- Painted copper-free aluminum with stainless steel external hardware
|
|
|
EM/EB/EQ Series Cenelec Rated Fixtures Use where European Certificate of Conformity is required for Zone 1 areas |
 |
- Compact size fixture, with special ground lug and labeling
- Utilizes bi-pin & quad-pin compact fluorescent lamps, as well as medium base incandescent and HID (35-150W) lamps.
|
|
 |
Back to top |
EZ Series Cenelec Rated Fixtures Use where European Certificate of Conformity is required for Zone 1 areas |
 |
- Full size fixture, with special ground lug and labeling
- Utilizes HID (50-400W) lamps
|
|
|
MIC/MAX Series Cenelec Rated HID Floodlights Use where restricted breathing type, Zone 2 area floodlighting is required |
 |
- Highly efficient asymmetric reflector design
- Copper-free aluminum body, glass lens, stainless steel fasteners
|
|
 |
Back to top |
800N Series Cenelec Rated HID Stainless Steel Floodlights Use where restricted breathing type, Zone 2 area floodlighting is required |
 |
- Highly efficient asymmetric reflector design
- Marine grade stainless steel body with toughened safety glass
|
|
|
EVO Series Cenelec Rated HID/Tungsten Halogen Floodlights Use where floodlighting is required in Zone 1 areas |
 |
- Offers optimum lighting levels with minimum maintenance costs
- Copper-free aluminum body, toughened glass window, SS fasteners
|
|
 |
Back to top |
LLI2/LLIE2 Series Cenelec Rated Non-Metallic Linear Fluorescent Fixtures Use where Cenelec Zone 2 fixtures are required for corrosive conditions |
 |
- FRP housing with single piece polycarbonate lens
- Available as emergency fixture with battery backup and self-testing/self-diagnostic electronics with LED status display
|
|
|
LLI1/LLIE1 Series Cenelec Rated Non-Metallic Linear Fluorescent Fixtures Use where Cenelec Zone 1 fixtures are required for corrosive conditions |
 |
- FRP housing with single piece polycarbonate lens
- Available as emergency fixture with battery backup and self-testing/self-diagnostic electronics with LED status display
|
|
 |
Back to top |